ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 118 of 545 2020-04-15
<format> parameter setting is never stored in NVM.
If AT+COPS=0 is issued after the switch-on, it causes a new attempt to select a network
operator and registers the module on the selected operator.
AT+COPS?
Read command returns current value of <mode>, <format>, <oper> and <AcT> in format
<format>. If no operator is selected, <format>, <oper> and <AcT> are omitted.
+COPS: <mode>[, <format>, <oper>,< act>]
If the module is deregistered, <format>, <oper>, and <act> parameters are omitted.
AT+COPS=?
Test command returns a list of quadruplets, each representing an operator present in the network.
The quadruplets list is ended with the range values of the <mode> and <formats> parameters.
The quadruplets in the list are closed between round brackets, separated by commas, the <oper>
parameter is returned in both formats.
+COPS: [quadruplets list (<stat>,<oper (in <format>=0)>,,<oper (in <format>=2)>,< act>),
(<stat>,<oper (in <format>=0)>,,<oper (in <format>=2)>,< act>), ...]
[,,(range of <mode>),(range of <format>)]
<stat> parameter is described in the Additional info section.
Additional info:
Meaning of the <stat> parameter.
Since with this command a network scan is done, this command may require some
seconds before the output is given.