3.13.25. AT#PADFWD - PAD Forward Character
PAD forward character
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#PADFWD=<char>[,<mode>]
Set command sets the char that immediately flushes pending data to socket opened by AT#SD
command
Parameters:
Name
Type
Default
Description
<char>
integer
13
specifies the ascii code of the char used to flush data
Value:
0÷255
:
ascii code of the char used to flush data
<mode>
integer
0
flush mode
Values:
0
:
normal mode
1
:
reserved
Use AT#PADCMD to enable the socket char-flush activity
AT#PADFWD?
Read command reports the currently selected <char> and <mode> in the format:
#PADFWD: <char>,<mode>
AT#PADFWD=?
Test command reports the supported range of values for parameters <char> and <mode>

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals