ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 71 of 545 2020-04-15
3.1.2.39. AT#PORTCFG - Connect Physical Ports to Service Access Points
This command allows to connect Service Access Points (software anchorage points) to the external physical
ports.
[1] Hardware User's Guide of the used module
AT#PORTCFG=<Variant>
Set command allows to connect Service Access Points to the external physical ports giving a great
flexibility. Examples of Service Access Points: AT Parser Instance #1, #2, #3, etc..
Parameter:
set port configuration. A short description, for each <Variant>
value, is reported in test command section. The range
depends on the product.
To enable the set port configuration, the module must be rebooted.
AT#PORTCFG?
Read command returns the requested and the active port configuration in the format:
#PORTCFG: <requested>,<active>
Additional info:
Parameters returned by the read command, in format:
#PORTCFG: <requested>,<active>
value showing the requested configuration that will
be activated on the next power ON.
value showing the actual configuration.
AT#PORTCFG=?
Test command returns a brief description of the supported ports arrangement solutions.
For each <Variant> are reported, on one row, the logical connections between a physical port
(USIF0, USB0, etc.) and a Service Access Point (AT#1, AT#2, etc.). Each row reports the logical