3.8.3. AT#ALARMPIN - Alarm Pin Configuration
This command allows to configure the ALARM Pin.
[1] Hardware User's Guide of the used module
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#ALARMPIN=<pin>
Set command allows to set a GPIO pin as ALARM pin.
Configuring a GPIO pin as ALARM pin is equivalent to setting it up with the ALT2 alternate
function. Therefore, a GPIO pin can be configured as ALARM pin also through the #GPIO
command. To have information on GPIO pins refer to document [1].
Parameter:
Name
Type
Default
Description
<pin>
integer
0
GPIO pin number.
Max is the number of GPIO pins provided by the module. For
information on the available GPIO pins use the test command.
Values:
0
:
no ALARM pin set
1÷Max
:
GPIO pin number
AT#ALARMPIN?
Read command returns the current value of the parameter <pin> in the format:
#ALARMPIN: <pin>
AT#ALARMPIN=?
Test command returns the supported values of parameter <pin>.

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals