ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 288 of 545 2020-04-15
3.7.10. AT#WAKE - Wake from Alarm Mode
Stop any alarm activity
AT#WAKE=<opmode>
Execution command stops any eventually present alarm activity and, if the module is in alarm
mode, it exits the alarm mode and enters the normal operating mode.
Parameter:
normal operating mode; the module exits the alarm mode and enters the
normal operating mode, any alarm activity is stopped (e.g. alarm tone
playing) and an OK result code is returned.
If #WAKE=0 command is issued after an alarm has been set with +CALA command, but
before the alarm has expired, it will answer OK but have no effect.
AT#WAKE?
Read command returns the operating status of the device in the format:
#WAKE: <status>
where:
<status>
0 - normal operating mode
1 - alarm mode or normal operating mode with some alarm activity.
AT#WAKE=?
Test command returns OK result code.
The alarm mode is indicated by status ON of hardware pin CTS and by status ON of
pin DSR; the power saving status is indicated by a CTS - OFF and DSR - OFF
status; the normal operating status is indicated by DSR - ON.
During the alarm mode the device will not make any network scan and will not
register to any network and therefore is not able to dial or receive any call or SM, the
only commands that can be issued to the MODULE in this state are the #WAKE and
#SHDN, every other command must not be issued during this state.