EasyManuals Logo

Telit Wireless Solutions ML865G1 At Commands Reference Guide

Telit Wireless Solutions ML865G1
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #273 background imageLoading...
Page #273 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 273 of 545 2020-04-15
3.7.2. AT+CALA - Alarm Management
This command is related to the alarm management.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT+CALA=<time>[,<n>[,<type>[,<text>[,<recurr>[,<silent>]]]]]
Set command stores in the internal Real Time Clock of the module an alarm time with respective
settings.
It is possible to set up a recurrent alarm for one or more days in the week.
• Currently just one alarm can be set.
• Alarms are not supported after disconnecting from power. Coin cell are supported. In case
of a power cut, alarm will be deleted and needs to be re-set.
When the RTC time reaches the alarm time then the alarm starts, the behavior of the module
depends on the setting <type> and if the module was already ON at the moment when the alarm
time had come.
Parameters:
Name
Type
Default
Description
<time>
string
-
current alarm time as quoted string in the format:
"yy/MM/dd,hh:mm:ss±zz"
Refer to +CCLK for the string meaning.
Empty string (+CALA="") deletes the current alarm and
resets all the +CALA parameters to the factory default
configuration.
"hh:mm:ss±zz" string must be used only when issuing
+CALA with parameter <recurr>.
<n>
integer
0
index of the alarm
Value:
0
:
the only value supported
<type>
integer
1
alarm behavior type
Values:
0
:
reserved
1
:
the module wakes up fully operative as if the ON/OFF button has been
pressed. If the module is already ON when the alarm times out, then it
does nothing.
2÷8
:
see Additional info section.
<text>
string
-
alarm code text string used in the URC +CALA. It has
meaning only if <type> is equal to 2, 5 or 6.
<recurr>
string
N/A
sets a recurrent alarm for one or more days in the week in the
following format:

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals