"<1..7>[,<1..7>[, ... ]]"
indicates if the alarm is silent or not
<type>=2
The module wakes up in "alarm mode" if at the alarm time it was powered OFF, otherwise
it remains fully operative. In both cases the module issues an unsolicited code every 3 s:
+CALA: <text>
Where <text> is the +CALA optional parameter previously set.
The module keeps on sending the unsolicited code every 3 s until a #WAKE or #SHDN
command is received or a 90 seconds timer expires. If the module is in "alarm mode" and it
does not receive the #WAKE command within 90s then it shuts down.
<type>=3
The module wakes up in "alarm mode" if at the alarm time it was powered OFF, otherwise
it remains fully operative. In both cases the module starts playing the alarm tone on the
selected path for the ringer (see command #SRP).
The module keeps on playing the alarm tone until a #WAKE or #SHDN command is
received or a 90 s time-out occurs. If the device is in "alarm mode" and it does not receive
the #WAKE command within 90s then it shuts down.
If alarm expires during a call alarm sound will stop when the call is disconnected.
<type>=4
The module wakes up in "alarm mode" if at the alarm time it was off, otherwise it remains
fully operative. In both cases the module brings the alarm pin high, provided that one has
been set (using #ALARMPIN or #GPIO) and keeps it in this state until a #WAKE or
#SHDN command is received or a 90 seconds timer expires. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90s then it shuts down.