3.1.3.7. ATS7 - Connection Completion Time-Out
This set command specifies the amount of time that the DCE shall allow between either answering a call
(automatically or by the ATA command) or completion of signaling of call addressing information to network
(dialing), and establishment of a connection with the remote DCE. If no connection is established during this
time, the DCE disconnects from the line and returns a result code indicating the cause of the disconnection.
ITU-T Recommendation V.25 ter
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Specific profile
No
-
2
ATS7=<tout>
Parameter:
Name
Type
Default
Description
<tout>
integer
60
defines time interval expressed in seconds
Value:
1÷255
:
available range
ATS7?
Read command returns the current value of S7 parameter.
The format of the numbers in output is always 3 digits, left-filled with 0s.

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals