ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 56 of 545 2020-04-15
TA buffer of unsolicited result codes is flushed to the TE when <mode>
1...3 is entered (OK response shall be given before flushing the codes)
Sending of URCs in the case of key pressings or display changes are currently not
implemented.
After +CMER has been switched on with e.g. AT+CMER=2,0,0,2 command (i.e. <bfr> is
0), URCs for all registered indicators will be issued only first time, if previous <mode>
was 0, for backward compatibility. Values shown by the indicators will be current
indicators values, not buffered ones. Subsequent +CMER commands with <mode>
different from 0 and <bfr> equal to 0 will not flush the codes, even if <mode> was set
again to 0 before. To flush the codes, <bfr> must be set to 1.
Although it is possible to issue the command when SIM PIN is pending, it will answer
ERROR if "message" or "smsfull" indicators are enabled in +CIND, because with pending
PIN it is not possible to give a correct indication about SMS status. To issue the
command when SIM PIN is pending you have to disable "message" and "smsfull"
indicators in +CIND first.
AT+CMER?
Read command returns the current setting of parameters, in the format:
+CMER: <mode>,<keyp>,<disp>,<ind>,<bfr>
AT+CMER=?
Test command returns the range of supported values for parameters <mode>, <keyp>, <disp>,
<ind>, <bfr>, in the format:
+CMER: (list of supported <mode>s),(list of supported <keyp>s), (list of supported <disp>s),(list
of supported <ind>s),(list of supported <bfr>s)