F6-08: Reset Communication Parameters
Determines whether communication-related parameters (F6-oo and F7-oo)
are reset when the drive is initialized using
A1-03.
No. Parameter Name Setting Range Default
F6-08 Reset Communication Parameters 0 or 1 0
Setting 0: Do Not Reset Parameters F6-oo and F7-oo when the Drive Is Initialized with A1-03
Setting 1: Reset F6-oo and F7-oo when the Drive Is Initialized with A1-03
Note: F6-08 is not reset when the drive is initialized, but does determine whether initializing the drive with A1-03 resets communication
parameters F6-oo and F7-oo.
u
CC-Link Parameters
Parameters F6-04, F6-10, F6-11, and F6-14 set up
the drive to operate on a CC-Link network. Refer to the option manual
for details on parameter settings.
u
MECHATROLINK-II Parameters
Parameters F6-20 through F6-26 set up the drive
to operate on a MECHATROLINK-II network. Refer to the option manual
for details on parameter settings.
u
MECHATROLINK-III Parameters
Parameters F6-20, F6-21, and F6-23 through F6-26 set
up the drive to operate on a MECHATROLINK-III network. Refer
to the option manual for details on parameter settings.
u
PROFIBUS-DP Parameters
Parameters F6-30 through F6-32 set up the drive
to operate on a PROFIBUS-DP network. Refer to the option manual for
details on parameter settings.
u
CANopen Parameters
Parameters F6-35 and F6-36 set up the drive
to operate on a CANopen network. Refer to the option manual for details on
parameter settings.
u
CompoNet Parameters
Parameters F6-40 and F6-41 set up the drive to operate on a CompoNet network. Refer to the option manual for details
on parameter settings.
u
DeviceNet Parameters
Parameters F6-50 through F6-63 set up the drive
to operate on a DeviceNet network. Refer to the option manual for details
on parameter settings.
5.6 F: Option Settings
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
175
5
Parameter Details

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20

Related product manuals