Malfunctions or problems caused by programs made by customers using DriveWorksEZ.
Other problems not due to defects in Yaskawa workmanship or materials.
Warranty service is only applicable within Japan. However,
after-sales service is available for customers outside of Japan
for a reasonable fee.
Contact your local Yaskawa representative for more information.
Exceptions
Any inconvenience to the customer or damage to non-Yaskawa products due to Yaskawa’s defective products whether
within or outside of the warranty period are NOT covered by warranty.
n
Restrictions
The drive was not designed or manufactured for use in devices or systems that may directly affect or threaten human lives
or health.
Customers who intend to use the product described in this manual for devices or systems relating to transportation, health
care, space aviation, atomic power, electric power, or in underwater applications must first contact their Yaskawa
representatives or the nearest Yaskawa sales office.
This product has been manufactured under strict quality-control guidelines. However, if this product is to be installed in
any location where failure of this product could involve or result in a life-and-death situation or loss of human life or in a
facility where failure may cause a serious accident or physical injury, safety devices must be installed to minimize the
likelihood of any accident.
u
Quick Reference
Easily Set Application-Specific Parameters
Preset parameter defaults are available for many applications. Refer to
Application Selection on
page 94.
Run a Motor of One-Frame Larger Capacity
When using this drive for variable torque loads such as fans and pumps, a motor one frame size larger can be used. Refer to C6-01: Drive Duty
Selection on page 150
Know the Details of Safety Measures
The functions listed below affect the safe operation of the drive. Ensure that the settings fit the application requirements prior to operation.
Operation of digital outputs during Auto-tuning. Rotational Auto-tuning allows for normal digital output
operation. Non-rotational Auto-tuning
does not allow for normal digital output operation.
Safe operations. Run by power on. Parameter setting b1-17.
LOCAL/REMOTE key effective during stop in drive mode. Parameter o2-01.
LED operator stop key priority selection. Parameter o2-02.
Enter press required after changing the keypad frequency reference. Parameter o2-05.
Operation interlock when program mode is selected. Parameter b1-08.
Replace the Drive
The removable terminal block with parameter backup function allows the transfer of parameter
settings after drive replacement. Refer to Dismantling the Removable Terminal Block on page
299.
Drive a Synchronous PM Motor
The V1000 drive can operate synchronous PM motors. Refer to Subchart A3: Operation with
Permanent Magnet Motors on page 92.
i.2 General Safety
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual