Loading...
B.5 China Localized Drive Default Values
Table B.5 Default Values of the China Localized Drive: CIMR-VBoo
Parameter Description
Control Mode (A1-02, E3-01)
V/f OLV PM
E1-04 Maximum Output Frequency 50.0 Hz 50.0 Hz
<1>
E1-06 Base Frequency 50.0 Hz 50.0 Hz
<1>
E1-07 Middle Output Frequency 2.5 Hz 3.0 Hz
E1-09 Minimum Output Frequency 1.3 Hz 0.5 Hz
<1>
E3-04 Motor 2 Maximum Output Frequency 50.0 Hz 50.0 Hz
E3-06 Motor 2 Base Frequency 50.0 Hz 50.0 Hz
E3-07 Motor 2 Middle Output Frequency 2.5 Hz 3.0 Hz
E3-09 Motor 2 Minimum Output Frequency 1.3 Hz 0.5 Hz
<1> Default setting is determined by the motor code set to parameter E5-01.
B.5 China Localized Drive Default Values