B.5 China Localized Drive Default Values
Table B.5 Default Values of the China Localized Drive: CIMR-VBoo
Parameter Description
Control Mode (A1-02, E3-01)
V/f OLV PM
E1-04 Maximum Output Frequency 50.0 Hz 50.0 Hz
<1>
E1-06 Base Frequency 50.0 Hz 50.0 Hz
<1>
E1-07 Middle Output Frequency 2.5 Hz 3.0 Hz
E1-09 Minimum Output Frequency 1.3 Hz 0.5 Hz
<1>
E3-04 Motor 2 Maximum Output Frequency 50.0 Hz 50.0 Hz
E3-06 Motor 2 Base Frequency 50.0 Hz 50.0 Hz
E3-07 Motor 2 Middle Output Frequency 2.5 Hz 3.0 Hz
E3-09 Motor 2 Minimum Output Frequency 1.3 Hz 0.5 Hz
<1> Default setting is determined by the motor code set to parameter E5-01.
B.5 China Localized Drive Default Values
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
381
B
Parameter List

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20

Related product manuals