8.5 Communication Options
Table 8.3 gives detailed information about the available options that allow Yaskawa drives to connect to communication
networks. A host controller can control and monitor the drive, read and change parameters by using a communication
option. Contact Yaskawa or your Yaskawa agent to order options.
Option Selection: Refer to Yaskawa catalog for more details on option selection and part numbers.
Option Installation: Refer to option manual for option installation instructions.
Table 8.3 Available Communication Options
Option Model Function
PROFIBUS-DP Communications Option SI-P3/V Connects to a PROFIBUS-DP network
CC-Link Communications Option SI-C3/V Connects to a CC-Link network
DeviceNet Communications Option SI-N3/V Connects to a DeviceNet network
CompoNet Communications Option SI-M3/V Connects to a CompoNet network
CANopen Communications Option SI-S3/V Connects to a CANopen network
EtherNet/IP Communications Option
SI-EN3/V
<1>
Connects to an EtherNet/IP network
MECHATROLINK-II Communications Option SI-T3/V Connects to a MECHATROLINK-II network
MECHATROLINK-III Communications Option SI-ET3/V Connects to a MECHATROLINK-III network
LonWorks Communications Option
SI-W3/V
<1>
Connects to a LonWorks network
EtherCAT Communications Option
SI-ES3/V
<1>
Connects to an EtherCAT network
PROFINET Communications Option
SI-EP3/V
<1>
Connects to a PROFINET network
Modbus TCP/IP Communications Option
SI-EM3/V
<1>
Connects to a Modbus TCP network
POWERLINK Communications Option
SI-EL3/V
<1>
Connects to a POWERLINK network
<1> Under development.
8.5 Communication Options
314
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20