Zebra ZD620 - POWER UP ACTION

Zebra ZD620
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
89
Printer Configuration Menus
POWER UP ACTION
Description: Set the action for the printer to take during the power-up sequence.
Accepted values:
CALIBRATE—Adjusts sensor levels and thresholds, determines the label length,
and FEEDs the media to the next web/gap.
FEED—FEEDs the labels to the first registration point.
LENGTH—Determines the label length using current sensor values, and FEEDs the
media to the next web/gap.
NOMOTION—Tells the printer not to move the media. You must manually ensure
that the web is positioned correctly, or press FEED to position the next web/gap.
SHORTCAL—Sets the media and web thresholds without adjusting sensor gain,
determines the label length, and FEEDs the media to the next web/gap.
Related ZPL command(s): ^MF
SGD command used: ezpl.power_up_action
Print Server web page: ViewandModifyPrinterSettings
>Calibration