Chapter 33 Error-Disable
GS2220 Series User’s Guide
309
33.2 Erro r- Disa ble Se tting s
Use this screen to go to the screens where you can configure error disable related settings. Click
Adva nc e d Applic a tio n > Errdisa ble in the navigation panel to open the following screen.
Fig ure 234 Advanced Application > Errdisable
The following table describes the labels in this screen.
33.3 Erro r- Disa ble Sta tus
Use this screen to view whether the Switch detected that control packets exceeded the rate limit
configured for a port or a port is disabled according to the feature requirements and what action you
configure, and related information. Click the Clic k he re link next to Errdisa b le Sta tus in the Adva nc e d
Applic a tio n > Errdisa ble screen to display the screen as shown.
Table 152 Advanced Application > Errdisable
LABEL DESC RIPTIO N
Errdisable Status Click this link to view whether the Switch detected that control packets exceeded the rate
limit configured for a port or a port is disabled according to the feature requirements and
what action you configure, and related information.
CPU protection Click this link to limit the maximum number of control packets (ARP, BPDU and/or IGMP)
that the Switch can receive or transmit on a port.
Errdisable Detect Click this link to have the Switch detect whether the control packets exceed the rate limit
configured for a port and configure the action to take once the limit is exceeded.
Errdisable Recovery Click this link to set the Switch to automatically undo an action after the error is gone.