Chapter 33 Error-Disable
GS2220 Series User’s Guide
313
33.6 Erro r- Disa ble Re c o ve ry C o nfig ura tio n
Use this screen to configure the Switch to automatically undo an action after the error is gone. Click the
Clic k He re link next to Errdisa ble Re c o ve ry in the Adva nc e d Applic a tio n > Errdisa ble screen to display
the screen as shown.
Fig ure 238 Advanced Application > Errdisable > Errdisable Recovery
The following table describes the labels in this screen.
Apply Click App ly to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Sa ve link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel Click Ca nc e l to begin configuring this screen afresh.
Table 155 Advanced Application > Errdisable > Errdisable Detect (continued)
LABEL DESCRIPTIO N
Table 156 Advanced Application > Errdisable > Errdisable Recovery
LABEL DESCRIPTIO N
Active Select this option to turn on the error-disable recovery function on the Switch.
Reason This field displays the supported features that allow the Switch to shut down a port or discard
packets on a port according to the feature requirements and what action you configure.
* Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Changes in this row are copied to all the entries as soon as you make them.
Timer Status Select this check box to allow the Switch to wait for the specified time interval to activate a port
or allow specific packets on a port, after the error was gone. Clear the check box to turn off this
rule.
Interval Enter the number of seconds (from 30 to 2592000) for the time interval.
Apply Click App ly to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Sa ve link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel Click Ca nc e l to begin configuring this screen afresh.