Chapter 5 Connecting Customer-Supplied Safety and Power Control Equipment to the CIP
102 Adept MV Controller User’s Guide, Rev. B
Figure 5-6. J-User 37 Pin D-sub Connector
J-User 37-pin D-sub
FM
CIP Internal Connections
User Supplied Connections
D
D
D
24 V
24 V
5 V
2
1
20
21
3
22
12
31
19
18
17
36
37
5 V
User 24V
CC1
L
N
G
Controller
Line
User AC Power On
12 V
-12 V
MCP
AWC
RS232
TX
RX
Remote MCP Connector
(use USER ESTOP and
USER ENABLE for MCP
Estop and hold-to-run
connections)
V
+
High Power
request
V
+
burned out bulb
notify (prevents High
Power enable)
Manual / Auto
(Auto = closed [|])
Local / Network
(Network = closed [|])
Central Control
High Power On / Off
- Momentary signal
>100 msec., <= 1 sec.
- Manual Auto in auto
- Local / Network in Network
Remote High Power
Power On / Off
(momentarty P.B. switch
lamp: 5 - 6V, 0.3A max.
If JP2 installed, them min.
current = 100mA )
High Power
On / Off
System
Power
CC1
JP2
1A PTC Fuse
4.7
VREF: 0.24V+
diode forward
voltage drop
4.7
Compact Interface Panel Remote Connections
-
+
Remote High Power on/off
(Momentary P.B. switch/lamp:
5 - 6V, 0.3A max. If JP2
installed, then min. current =
100mA.)
Central Control High Power
on/off
-Momentary signal
>100msec., <= 1 sec.
-Manual/Auto in Auto
-Local/Network in Network
User AC Power On
Remote MCP connector (use
USER ESTOP and USER
ENABLE for MCP E-Stop and
hold-to-run connections)
VREF: 0.24V+
diode forward
voltage drop
V
+
burned out bulb
notify (prevent High
Power enable)
User-Supplied Connections
CIP Internal connectors
V
+
High Power
request
User 24V
System
Power
High Power
on/off
Manual/Auto
(Auto = closed [|])
Local/Network
(Network = closed [|])
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com