*Correlation template too big* (–754)
Explanation: A vision correlation template has been defined that is too large.
User action: Redefine a smaller template
Cursor at column n (None)
Explanation: The SEE editor WHERE extended command is reporting the current
column position of the cursor.
User action: None. This is an informational message.
*Database manager internal error* (–859)
Explanation: This error indicates that the system has encountered an inconsis-
tency.
User action: Contact Adept Application Engineering. Please record the details of
exactly what you were doing at the time the error occurred.
*Data checksum error* (–510)
Explanation: An error was detected while transferring information to or from an
external device.
User action: Attempt the transfer again. If the problem persists, contact Adept
Customer Service.
*Data error on device* (–522)
Explanation: An error was detected while attempting to read information from an
external device, possibly because a diskette has been damaged or
was not formatted properly.
User action: Attempt the read again. Make sure the correct diskette is being
used, that it is properly installed in the drive, and that it is format-
ted. (Recall that formatting a diskette erases its contents.)
*Data overflow* (–755)
Explanation: The vision binary correlation hardware has found more matches
within the search area than it can process.