*Controller not in manual mode* (–304)
Explanation: An attempt has been made to perform an operation that requires the
controller to be in manual mode when it is not in manual mode. If
you do not have a front panel connected, the controller is assumed
to be in automatic mode.
User action: Select manual mode by moving the switch on the front panel to the
manual position, or by activating the proper switch on a custom
control panel. Retry the previous operation.
*Controller not in network mode* (–317)
Explanation: An attempt has been made to use a serial line configured for net-
work use, but the controller is not in network mode. If you do not
have a front panel connected, the controller is assumed to be in local
mode.
User action: Select network mode by moving the switch on the front panel to the
network position, or by activating the proper switch on a custom
control panel. Retry the previous operation.
*Controller overheating* (–631)
Explanation: The temperature sensor in the controller power supply has detected
an overheating condition. High power is switched off.
User action: Make sure the controller fans are operating and are not obstructed.
Make sure the fan filters are clean. Power down the controller to let
it cool off.
*Control structure error* (–473)
Explanation: An incomplete control structure has been encountered during pro-
gram execution.
User action: Edit the program to correct the control structure.
*Control structure error * Step nn (–472)
Explanation: V
+
has detected an incomplete or inconsistent control structure at
the specified step when exiting the program editor, loading a pro-
gram, or processing a BPT command.
User action: Edit the program to correct the control structure. (Note that the
actual error may not be at the indicated step.) If the error occurs in
response to a BPT command, you can type dir /? to identify pro-