EasyManua.ls Logo

adept technology MV - Page 286

adept technology MV
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
  !"
  9&/
During MANUAL mode, releasing this switch performs a con-
trolled power-off rather than an E-STOP.
User action: Hold the user enable switch and reenable HIGH POWER as desired.
If the switch was already pressed, check the switch and the associ-
ated connectors and wiring.
Executing in DRY.RUN mode (50)
Explanation: The DRY.RUN switch is enabled and program execution has been
requested. Thus, no motion of the robot will occur.
User action: None unless motion of the robot is desired. In that case, abort execu-
tion of the program and disable the DRY.RUN switch.
*Expected character(s) not found* (–745)
Explanation: While training characters for subsequent optical character recogni-
tion (OCR), the number of characters in the given string did not cor-
respond to the number of characters found in the training window.
Character training has been aborted.
User action: Make sure the given string matches the characters in the training
window.
*[Fatal] Addr Err* at aaaaaa m:n I=xxxx, A=aaaa, F=ff (None)
Explanation: An internal problem has occurred with the V
+
software or with the
system hardware.
User action: It would be appreciated if you would report the error to Adept
Application Engineering. Please include the details of the error mes-
sage and exactly what you were doing at the time the error
occurred.
To save programs that are in memory, you can restart V
+
tempo-
rarily by pressing CTRL+G. The robot servos will not function, but
you can STORE the programs. Then power down the controller and
restart the system.
*[Fatal] Bus Err* at aaaaaa m:n I=xxxx, t=aaaa, F=ff (None)
Explanation: A computer error occurred because of a bad read from memory,
because of noise on the internal data bus, or because of a hardware
problem.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com