*Invalid statement label* (–463)
Explanation: The program statement label was not an integer from 0 to 65535.
User action: Reenter the line with a valid label.
Invalid steps will be changed to ? lines (None)
Explanation: The AUTO.BAD extended command has been used to change the
action to be taken when an invalid line is detected while editing.
Subsequently, such a line will automatically be changed to a bad
line with a question mark in column one.
User action: None. This is an informational message.
*Invalid VFEATURE access* (–801)
Explanation: A VFEATURE function has been used to access, from the vision sys-
tem, data that is not valid. In particular, after a VLOCATE instruc-
tion in no-wait mode, the vision data is invalid if VFEATURE(1)
returns the value FALSE.
User action: Edit the program to ensure that, after a no-wait VLOCATE, no
VFEATURE accesses [other than VFEATURE(1)] occur if the vision
data is indicated by VFEATURE(1) to be invalid.
*Invalid vision argument* (–735)
Explanation: An argument for a vision function, program instruction, or com-
mand is not in the accepted range.
User action: Check the acceptable range of arguments for the function, program
instruction, or command being used. Check the vision calibration to
make sure the scaling is reasonable.
*Invalid vision X/Y ratio* (–727)
Explanation: A VPUTCAL instruction has been used to pass vision calibration
data to the AdeptVision system, and the x-scale to y-scale is not in
the acceptable range.
User action: Make sure the program reads the calibration data from a valid data
file, or make sure valid values are asserted by the program.