2;
*Timeout: MCP enable switch not toggled* (–649)
Explanation: V
+
did not enable high power because you failed to toggle properly
the MCP enable switch on the manual control pendant.
User action: Do one or more of the following: (1) when toggling the MCP enable
switch, release it for a minimum of about two seconds and a maxi-
mum of ten seconds, and then press it back in; and (2) make sure
that you are pressing the MCP enable switch and not the
RUN/HOLD button by mistake.
*Too many arguments* (–553)
Explanation: Too many arguments were specified for the last command or
instruction.
User action: Reenter the command or instruction but with the correct number of
arguments.
*Too many array indices* (–474)
Explanation: The specification of an array element contains more than three
indexes.
User action: Reenter the line with the correct number of indexes.
*Too many closeable windows* (–554)
Explanation: The names of too many graphics windows have been specified to
appear in the pull-down under the Adept logo in the status line at
the top of the screen.
User action: Specify all subsequent windows as /NOCLOSEABLE, or delete
some existing windows that appear in this pull-down.
*Too many icons* (–556)
Explanation: An attempt has been made to define more graphic icons than the
system is configured to support.
User action: Delete any icons that are no longed needed. If necessary, use the
CONFIG_C utility program to reconfigure your V
+
system to sup-
port more icons.