*Unexpected end of file* (–504)
Explanation: (1) If a file was being loaded from the disk, the end of the file was
encountered unexpectedly.
(2) If a program is reading a file, this error code merely indicates that
the end of the file has been reached and should not be interpreted as
a real error.
(3) This message results if a CTRL+Z is pressed in response to a pro-
gram PROMPT.
(4) A break condition was detected on a serial line.
User action: (1) Try again to read the file.
(2) Close the file and continue program execution.
(3) Treat the program as having been aborted early by user request.
%2'),>*:?@
*Unexpected PSS state* Code nnn (–1110)
Explanation: The software has detected an unexpected change in the power
sequencing control hardware. The code value indicates what state
has been encountered. This error should never be seen, and may
indicate a software or hardware problem on either the AWC or CIP.
User action: If safe to do so, attempt to enable HIGH POWER and note any dif-
ferent error messages that occur. If this error persists, contact Adept
Customer Service.
*Unexpected text at end of line* (–451)
Explanation: The previous command or instruction could not be recognized by
V
+
, possibly because of a mistyped function name or because an
argument was specified where none is allowed.
User action: Reenter the line, correcting the syntax error.
*Unexpected zero index* Belt n (–1012)
Explanation: A zero index signal was received from the encoder for this motor
belt at an unexpected time. The encoder may be gaining or losing
counts, there may be a hardware problem with the zero index sig-
nal, or the Counts per zero index configuration parameter may be
set incorrectly.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for adept technology MV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the adept technology MV and is the answer not in the manual?

adept technology MV Specifications

General IconGeneral
Brandadept technology
ModelMV
CategoryController
LanguageEnglish