9960 Self-Propelled Peanut Combine Operation
MAN091 06/03/05 101
Starting the Engine
7. Turn the key switch to the ON position. The
buzzer will sound once due to low oil
pressure.
8. Turn the key switch to ignition position. The
following should happen:
a. The engine oil pressure warning, hydro
charge pressure warning, and separator
drive pressure warning lights will come
on.
b. The parking brake indicator light will
come on if the parking brake has been
applied; the buzzer will sound one short
pulse.
c. If the amber voltage light comes on, the
battery voltage is low and the combine
may not start.
9. Turn the key switch clockwise to start. All
lights on the warning display panel will
come on. Release the key when the
engine starts.
Overhead Panel
CAUTION
Sound the horn before starting the engine
to clear people away from the combine.
IMPORTANT!
To prevent starter damage,
do
NOT operate starter for more than 30
seconds at a time. If the engine does not
start, wait at least two minutes before
trying again.
After the engine starts, all lights except the
parking brake light should be out. If any
other light stays on, stop the
engine and
correct the problem.