Chapter 8
8.4 Menu DTrack2
8.4.4 Search for new hardware
Without the need of restarting the controller you can dynamically analyse your system
for changes in configuration (e.g. added or removed cameras, ART radio transceiver).
Therefore proceed as follows:
connect a new camera to the controller
wait until the camera has finished booting
within DTrack2 press F2 to perform a search for new hardware
check if the camera has been recognized successfully (e.g. by opening camera
settings F7’)
start the measurement, the message ’(re-)calibration required!’ should appear in
red color inside the Monitor 2DOF display of the corresponding camera (see chapter
8.3.3.1 on page 135 for details)
perform a room re-calibration 8.6.3.3 on page 170, added cameras are automatically
marked as moved in the room re-calibration dialogue.
Z
DTrack2 is able to operate when cameras have been added or removed;
for best performance it is highly recommended to perform a recalibra-
tion
8.4.5 Controller standby
Force the controller to go into standby mode with this command. You can restart the
controller manually or by using Wake On LAN. Please refer to chapter 8.2.3 on page 126
for more details.
8.4.6 Controller reboot
Reboot the controller with this command.
8.4.7 Quit
Quit DTrack2 frontend software. In case the system is still in measurement mode, a
confirmation window will show up. You may leave the active measurement running, the
frontend software will quit anyway.