5 ART Tracking Controllers
You can also enter a slave hostname or IP address directly in case you have set a spe-
cific static IP address.
Mark the desired controller and press Select to assign this controller to the cascaded
system. It will then appear on the left-hand side of the dialogue in the list of the Selected
controllers. Repeat these steps if you want to add more single controllers to the cascade.
To remove controllers from the cascaded system simply select the corresponding con-
trollers in the list of the Selected controllers by left-clicking and press button Deselect’.
The checkbox wake on LAN enables synchronized start-up of the master and all slave
controllers. Starting of the cascade will take 3-4 minutes as the master has to boot up
first and then wake up the slave(s). The changes will be accepted by the system if you
press OK ’. Settings (e.g. flash intensity, sync groups) of all cameras inside the cascade
can now be edited through the Settings Cameras dialogue. The next time you start the
measurement all cameras inside the cascade can be viewed through the Monitor 2DOF
display.
Z
Shutdown of master and slave controller(s) is always synchronized.
Tick the option wake on LAN to also start-up the slave controller(s)
automatically.
Z
Before continuing, please double-check whether a BNC connection
for synchronization has been established between master (OUT1) and
slave(s) (EXT.In).
Now, you can proceed with calibrating the room as usual. Please refer to chapter 4.8.3
on page 51 where room calibration is explained.