BM5030 with Safety Function
Instruction handbook bmaXX 5000
Document No.: 5.09021.19
331
of 346
B
D.6.1 Connection data of BM5030 with safety function
NOTE!
To ensure sufficient current load capacity of the connections, adhere to the specified
torques!
Connection
cross section
Connection
method
Torque Load capacity
Power supply
1U1, 1V1, 1W1
BM5030
with
safety
function
Max. 25 mm² Screw terminal Min. 4.0 Nm
Max. 4.5 Nm
Refer to ZFuses–
from page 277
Power supply
PE
Min. 10 mm² Cable lug for M5 Min. 2.2 Nm
Max. 3.0 Nm
-
Torque Max load
capacity of the bar
DC link
1C1 and 1D1
BM5030
with
safety
function
DC link bar Min. 2.2 Nm
Max. 3.0 Nm
130 A
Connection
cross section
Connection
method
Torque Load capacity
X101
Connection for
additional DC link
capacitance
BM5030
with
safety
function
Max. 6 mm² Plug connector,
spring-clamp
connection
-Max. 41A
Connection
cross section
Connection
method
Load capacity
X200 (SELV/PELV)
24 V power supply
Max. 1.5 mm²
(2 wire, 2 pin)
Plug connector,
spring-clamp
connection
Plug connector max. 16 A