Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
123
of 814
3
3.4.4 Asynchronous Motor
The asynchronous motor is operated with a temperature adapter and a slip set point. The
slip is calculated from the temperature-independent slip frequency, the I
d
-current actual
value and the flux actual value.
3.4.4.1 ProDrive Asynchronous Motor
Figure 42: ProDrive asynchronous motor
3.4.4.2 Lh-characteristic
BM5000 can consider a non-linear Lh-characteristic for motor control. This can be en-
tered manually or can be identified in idle mode.
Manual input of the Lh-characteristic Z123.33–
m Lh dependent on magnetizing current
m Flux dependent on magnetizing current