EasyManua.ls Logo

Baumuller b maXX BM5800 - Switch-On Behavior; Changing, Loading, Copying and Storing Parameters; Identification of Parameter Set and Data Sets

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
319
of 814
3
procedure), the device writes the standard values (default setting) to the parameters
when switched on again.
3.5.2.5 Switch-On Behavior
After the b maXX
is switched on, all parameters are loaded with the stored data. The
device activates Data Set 1. Unconfigured data sets are set to default values.
3.5.2.6 Changing, Loading, Copying and Storing Parameters
Changes to parameter values (e.g. by ProDrive or via a Fieldbus) only affect the device's
working memory. If changes are also to be preserved after the next switch-on of the de
-
vice, the parameters must be explicitly stored in the device. All the parameters in all the
created data sets are always stored.
With the aid of data set commands, the values of parameters in created data sets can be
loaded individually or completely into the working memory.
The data set copy function permits copying of the parameter values from a created source
data set to a different target data set. If the target data set has not been created yet, it will
be automatically created by the device. If the target data set has already been created,
the original parameter values will be overwritten.
Using the ProDrive Up/Download function on the "Data Set Management" page, param-
eters can also be saved to a PC data storage medium or written back to the device.
3.5.2.7 Identification of Parameter Set and Data Sets
There is the parameter Z105.11 for identifying of the complete parameter set for a de-
vice.
For identifying individual data sets the following parameter are available:
Parameter Data Type Meaning
Z105.4
Data Set Name
STRING Freely selectable text name for the data set
Z105.5
Data Set
Identification Number
UDINT You can assign each data set (DS 1 to DS 7)
a unique number from 0
to 4294967295
here

Table of Contents