3.4
3.4.1.3 Description of the Parameters
129.3 Hardware Id
The hardware identifier has the format:
33.YYNN.BBA01 Example: 33.0815.02D04
130.1 Heat sink temperature FLOAT 0 1000 0 °C 1:1 X
130.2 Interior temperature FLOAT 0 1000 0 °C 1:1 X
130.3 DC link actual voltage FLOAT 10 1000 10 V 1:1 X
130.8 Mains voltage FLOAT 0.0e+0 1000 0.0e+0 V 1:1 X
130.9 Fan mode UINT 0x0000 0x3 0x0001 1:1 X
130.10 Mode UINT 0x0000 0xFFFF 0x0000 1:1 X
130.12 Heatsink temperature
warning threshold
UINT 0 0xFFFF 75 °C 1:1 X
130.13 Interior temperature
warning threshold
UINT 0 0xFFFF 55 °C 1:1 X
130.15 PWM frequency UINT 2 16 8 kHz 1:1 X X
130.18 I offset phase U FLOAT -2.56e+02 2.56e+02 0.0 A 1:1.414 X
130.19 I offset phase V FLOAT -2.56e+02 2.56e+02 0.0 A 1:1.414 X
130.20 I offset phase W FLOAT -2.56e+02 2.56e+02 0.0 A 1:1.414 X
130.24 Phase error delay time UINT 0 65535 0 ms 1:1 X
130.25 Mains failure delay UINT 0 6000 0 ms 1:1 X
130.28 Actual ground fault cur-
rent
FLOAT 0 100 0 A 1:1 X
130.29 Chopper threshold FLOAT 300 780 780 V 1:1 X X
130.34 Status STO module UINT 0 0xFFFF 0 1:1 X
130.37 Udc threshold for mains
failure
FLOAT 10 1000 450 V 1:1 X X
130.38 Udc hysteresis for
mains failure
FLOAT 10 500 50 V 1:1 X X
130.40 Operation time UDINT 0 0xFFFFFFFF 0 s 1:1 X
130.41 Actual PWM frequency UINT 2 16 8 kHz 1:1 X
175.3 Max. device control
cabin temperature
UINT 0 55 40 Grad
C
1:1 X X
175.4 Max. device altitude UINT 0 5000 1000 m 1:1 X X
175.5 Max. device mains volt-
age
UINT 0 530 400 V 1:1 X X
175.6 Max. device DC link
voltage
UINT 0 760 540 V 1:1 X X
175.7 PU max.continuous cur-
rent actual value
FLOAT 0 1000 4 A 1:1 X
175.8 PU I2t max. continuous
current actual value
FLOAT 0 1000 4 A 1:1 X