Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
222
of 814
3.4
Standardization
The latched values are available in the 64 bit format (32 bit revolutions Z124.5–,
Z124.7–, Z124.9–, ... and 32 bit angle Z124.6–, Z124.8–, Z124.10–, ...) and in 32 bit
format (Z124.31– to Z124.34–)
The 32 bit format offers different scaling types (see Z124.30–):
m n bit revolutions + m bit angle, n + m = 32
m Scaling with the Factor Group
m Scaling with the actual position value modulo
3.4.12.1 ProDrive Measuring Encoder
Figure 69: ProDrive Measuring Encoder
3.4.12.2 Parameter overview
Functional block: FbTouchProbe [124]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
124.1 Configuration mode DWORD 0 0xFFFFFFFF 0 1:1 X X
124.2 Activation command WORD 0 0xFFFF 0 1:1 X X
124.3 Status DWORD 0 0xFFFFFFFF 0 1:1 X X