Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
395
of 814
3
3.6.6.2 Description of the Parameters
168.1 Status
Status of the Motor potentiometer
168.2 Mode
Operating mode of the Motor potentiometer
Bit no. Meaning
0 1: Motor potentiometer active
3 … 1 Reserved
4 1: Ramp-up final value at Motor potentiometer+ reached
5 1: Ramp-down final value at Motor potentiometer- reached
6 1: Button Motor potentiometer+ depressed
7 1: Button Motor potentiometer- depressed
8 1: Motor potentiometer+ active
9 1: Motor potentiometer- active
10 1: Error at writing on the target parameter (e.g. value greater than maxi-
mum value)
15 ... 11 Reserved
Bit no. Meaning
0 0: Disable Motor potentiometer
1: Enable Motor potentiometer
1 0: Motor potentiometer+ off
1: Motor potentiometer+ on
2 0: Motor potentiometer- off
1: Motor potentiometer- on
3 Synchronization of the Motor potentiometer- output at activation
0: Output is synchronized to the ramp function generator parameter
Z110.5 Input 16 bit
1: Output is set to 0
4 Evaluation of the Motor potentiometer +/-
0: Edge sensitive
1: Level sensitive
15 … 5 Reserved