3.5.4.1 Parameter overview
Functional block: FbInfoMgr [100]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
100.1 Error command UINT 0 65535 0 1:1 X
100.2 Error count UINT 0 20 0 1:1 X
100.3 Error information RE-
CORD
X
100.4 Error reaction RE-
CORD
X
100.5 First error UDINT 0 5000 0 1:1 X
100.7 Error communication
mode
UINT 0 0xFFFF 0 1:1 X
100.8 Error reaction actual
value
INT -5 3 -1 1:1 X
100.9 Error reaction set value INT -5 3 -1 1:1 X
100.11 Launch application error UDINT 0 0xFFFFFFFF 0 1:1 X
100.12 Error count RAM log UINT 0 0xFFFF 0 1:1 X