Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
203
of 814
3
3.4.10 Digital Inputs
3.4.10.1 Digital inputs at axis units
On the axis units, digital inputs DI1 (axis 1) and DI2 (axis 2) are permanently linked to the
"Measuring probe" function.
3.4.10.2 Parameter overview
Functional block: DigInputs [116]
Function DI1 DI2
Measuring probe-1 HW
Measuring probe-2 HW
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
116.1 Status digital inputs DWORD 0 0xFFFFFFFF 0 1:1 X X
116.2 Mode digital input 1 WORD 0 0xFFFF 0 1:1 X X
116.3 DI1 Axis index UINT 0 255 0 1:1 X X
116.4 Target number digital
input 1
UDINT 0 0xFFFFFFFF 0 1:1 X X
116.5 Bit selection digital input
1
DWORD 0 0xFFFFFFFF 0 1:1 X X
116.6 Set bit pattern for LOW
state digital input 1
DWORD 0 0xFFFFFFFF 0 1:1 X X
116.7 Set bit pattern for HIGH
state digital input 1
DWORD 0 0xFFFFFFFF 0 1:1 X X
116.8 Mode digital input 2 WORD 0 0xFFFF 0 1:1 X X
116.9 DI2 Axis index UINT 0 255 0 1:1 X X
116.10 Target number digital
input 2
UDINT 0 0xFFFFFFFF 0 1:1 X X
116.11 Bit selection digital input
2
DWORD 0 0xFFFFFFFF 0 1:1 X X
116.12 Set bit pattern for LOW
state digital input 2
DWORD 0 0xFFFFFFFF 0 1:1 X X
116.13 Set bit pattern for HIGH
state digital input 2
DWORD 0 0xFFFFFFFF 0 1:1 X X