3.10.2 Oscilloscope function
The b maXX
controllers offers an integrated oscilloscope function for quick and easy
commissioning.
Range of oscilloscope function:
3.10.2.1 Parameter overview
Functional block: FbRsp [101]
Number of channels: 8
Sampling time: 2
n
* 125 µs (n = 0....65535)
Recording: triggered or not triggered
Triggering: m through internal status changes,
m Size change or
m external digital or analog inputs
Number of Triggers: 1
Trigger time in relation to
memory depth:
Recording after-running period parameterizable
(which means recording with or without prior
history related to the trigger event)
Trigger sources: m Digital signals (selection of relevant bits
through bit masks is possible) e.
g.:
n Status change
n Error or warning events
n external digital inputs
m analog signals
n Target or actual values
n Analog inputs
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
101.1 Status INT 0 5 0 1:1 X X
101.2 Command INT 0 7 0 1:1 X X
101.3 Channel 0 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.4 Channel 1 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.5 Channel 2 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.6 Channel 3 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.7 Channel 4 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X