System
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
52
of 814
3.3
3.3.1.2 Description of the Parameters
1.1 System Clock
Operating time of the controller in seconds.
1.2 System Ticks RT1
Display of the value of a counter which is incremented in TASK_RT1.
102.22 Fieldbus controller firm-
ware build number
UDINT 0 0xFFFFFFFF 0 1:1 X X
102.23 Board data command UINT 0 0x1000 0 1:1 X
102.24 Board data status UDINT 0 0xFFFF 0 1:1 X X
102.25 Hardware board identifi-
cation
STRING 1:1 X
102.26 Circuit board assembly STRING 1:1 X
102.28 Hardware date STRING 1:1 X
102.29 Hardware name STRING 1:1 X
102.30 Controller serial number UDINT 0 0xFFFFFFFF 0 1:1 X
102.31 Controller article num-
ber
UDINT 0 0xFFFFFFFF 0 1:1 X
102.32 Device serial number UDINT 0 0xFFFFFFFF 0 1:1 X
102.33 Device article number UDINT 0 0xFFFFFFFF 0 1:1 X
102.35 Device type code STRING 1:1 X
102.39 Fpga Id CU UDINT 0 0xFFFFFFFF 0 1:1 X X
139.1 Password UINT 0 0xFFFF 0 1:1
139.2 Baudrate UDINT 9600 115200 38400 1:1 X
139.4 Number of axes UDINT 1 2 2 1:1 X X
139.23 System command UDINT 0 0xFFFFFFFF 0 1:1
139.25 Switch-on time UDINT 0 0xFFFFFFFF 0 s 1:1 X X
158.1 Real time load FLOAT 0 1 0 % 1:1 X X
158.2 Real time load average FLOAT 0 1 0 % 1:1 X X
158.3 Max real time load FLOAT 0 1 0 % 1:1 X X
158.4 Interrupt load FLOAT 0 1 0 % 1:1 X X
158.5 Interrupt load average FLOAT 0 1 0 % 1:1 X X
158.6 Interrupt load max FLOAT 0 1 0 % 1:1 X X