Operating Modes
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
630
of 814
3.8
Figure 172: Compensating controller for acceleration
If the speed ramp was set too steep at a high load torque, it can happen that the drive
cannot be accelerated furthermore. In this case the frequency can be reduced at a con
-
stant frequency (bit 7 of Z166.1) to enable the drive acceleration.
3.8.9.2 Current control
If a specified torque is required to operate at low frequencies the current control at low
frequencies (bit 3 of
Z166.1) is recommended. An additional voltage (Z166.20) is ap-
plied at the set frequency threshold (Z166.17) via a PI controller, so that at least the set
current (Z133.22) or maximum current (settable via bit 8 of parameter Z166.1) is ap-
plied to the motor.
Figure 173: Current control