3.8.9.3 Parameter overview
Functional block: FbUfChart [166]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
166.1 Mode UINT 0 0xFFFF 0 1:1 X
166.2 State UINT 0 0xFFFF 0 1:1 X
166.3 Current threshold motor FLOAT 0 1 1 % 1:100 X
166.4 Current threshold gener-
ator
FLOAT 0 1 1 % 1:100 X
166.5 Zero voltage FLOAT 0 100 1 V 1:1 X
166.6 Input reference fre-
quency
DINT -1073741824 1073741824 0 % 107374
1824:
100
X X
166.7 Rising time FLOAT 0.01 100000 1 s 1:1 X
166.9 Slip compensation FLOAT 0 1000 0 Hz/A 1:1 X
166.10 Maximum frequency FLOAT 0 1000000 100 Hz 1:1 X
166.11 Time constant current
filter
FLOAT 0 100000 0 ms 1:1 X
166.12 Frequency Umax FLOAT 1 1e9 50 Hz 1:1 X
166.13 Maximum voltage FLOAT 0 1000 380 V 1:1 X
166.14 Kp acceleration control-
ler
FLOAT 0 1e9 0.1 Grad/s 1:1 X
166.15 Tn acceleration control-
ler
FLOAT 0 1e9 20 ms 1:1 X
166.17 Frequency threshold FLOAT 0 1e9 2 Hz 6.28318
53 : 1
X
166.18 State frequency reduc-
tion
UINT 0 0xFFFF 0 1:1 X
166.19 Frequency reduction FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.20 Additional voltage FLOAT -1e9 1e9 0 V 1:1 X
166.21 Frequency f0 FLOAT 0 0xFFFFFFFF 0 Hz 6.28318
53 : 1
X
166.22 Reference frequency FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.23 Additional frequency FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.24 Frequency of ramp gen-
erator
FLOAT -1e9 1e9 0 Hz 360:1 X
166.25 Kp speed correction
controller
FLOAT 0 1e9 0 1:1 X
166.26 Tn speed correction
controller
FLOAT 0 1e9 0 ms 1:1 X
166.27 Time constant slip filter FLOAT 0 100000 100 ms 1:1 X