EasyManua.ls Logo

Baumuller b maXX BM5800 - Parameter Overview

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
631
of 814
3
3.8.9.3 Parameter overview
Functional block: FbUfChart [166]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
166.1 Mode UINT 0 0xFFFF 0 1:1 X
166.2 State UINT 0 0xFFFF 0 1:1 X
166.3 Current threshold motor FLOAT 0 1 1 % 1:100 X
166.4 Current threshold gener-
ator
FLOAT 0 1 1 % 1:100 X
166.5 Zero voltage FLOAT 0 100 1 V 1:1 X
166.6 Input reference fre-
quency
DINT -1073741824 1073741824 0 % 107374
1824:
100
X X
166.7 Rising time FLOAT 0.01 100000 1 s 1:1 X
166.9 Slip compensation FLOAT 0 1000 0 Hz/A 1:1 X
166.10 Maximum frequency FLOAT 0 1000000 100 Hz 1:1 X
166.11 Time constant current
filter
FLOAT 0 100000 0 ms 1:1 X
166.12 Frequency Umax FLOAT 1 1e9 50 Hz 1:1 X
166.13 Maximum voltage FLOAT 0 1000 380 V 1:1 X
166.14 Kp acceleration control-
ler
FLOAT 0 1e9 0.1 Grad/s 1:1 X
166.15 Tn acceleration control-
ler
FLOAT 0 1e9 20 ms 1:1 X
166.17 Frequency threshold FLOAT 0 1e9 2 Hz 6.28318
53 : 1
X
166.18 State frequency reduc-
tion
UINT 0 0xFFFF 0 1:1 X
166.19 Frequency reduction FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.20 Additional voltage FLOAT -1e9 1e9 0 V 1:1 X
166.21 Frequency f0 FLOAT 0 0xFFFFFFFF 0 Hz 6.28318
53 : 1
X
166.22 Reference frequency FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.23 Additional frequency FLOAT -1e9 1e9 0 Hz 6.28318
53 : 1
X
166.24 Frequency of ramp gen-
erator
FLOAT -1e9 1e9 0 Hz 360:1 X
166.25 Kp speed correction
controller
FLOAT 0 1e9 0 1:1 X
166.26 Tn speed correction
controller
FLOAT 0 1e9 0 ms 1:1 X
166.27 Time constant slip filter FLOAT 0 100000 100 ms 1:1 X

Table of Contents