Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
268
of 814
3.4
3.4.17 Synchronization
3.4.17.1 Parameter overview
Functional block: FbSynchronisation[156]
3.4.17.2 Description of the Parameters
156.1 Mode
Switch on or switch off synchronization to fieldbus signal.
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
156.1 Mode UINT 0 1 0 1:1 X X
156.2 Status UINT 0 0xFFFF 0 1:1 X X
156.3 Sync tolerance UINT 0 0x1FFF 1000 µs 1000:20 X X
156.4 Sync offset DINT -2147483648 2147483647 0 µs 1000:20 X X
156.5 Fieldbus cycle UDINT 0 4294967295 0 µs 1000:20 X X
156.6 Fieldbus jitter DINT -2147483648 2147483647 0 µs 1000:20 X X
156.7 Sync error DINT -2147483648 2147483647 0 µs 1000:20 X X
156.8 Max. jitter positive DINT 0 262144 0 µs 1000:20 X
156.9 Max. jitter negative DINT -262144 0 0 µs 1000:20 X
156.15 Time fieldbus write
access
DINT -500000 500000 0 µs 1000:20 X X
156.16 Time DSP read access DINT -500000 500000 0 µs 1000:20 X X
156.17 Time DSP write access DINT -500000 500000 0 µs 1000:20 X X
156.18 Time fieldbus read
access
DINT -500000 500000 0 µs 1000:20 X X
156.19 Time fieldbus read to
DSP read
DINT -500000 500000 0 µs 1000:20 X X
Bit Meaning
0 0: Synchronization is switched off
1: Synchronization is switched on
1 0: Automatic adjustment of the Sync offset Z156.4–
1: Manual adjustment of the Sync offset Z156.4–