Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
389
of 814
3
3.6.5.8 Parameter Overview
Function block: FbKurvengenerator[159]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
159.1 Mode WORD 0 0x00FF 0 1:1
159.2 Cam options
curve generator options
WORD 0 0xFFFF 0 1:1 X
159.3 Status UINT 0 0xFFFF 0 1:1 X
159.4 List index UINT 0 0xFFFF 0 1:1 X
159.5 List entries UINT 0 0xFFFF 512 1:1 X
159.6 Cyclic curve offset UDINT 0 0xFFFFFFFF 0 1:1 X
159.7 Reference parameter UDINT 0 0xFFFFFFFF 0 1:1 X
159.8 Reference axis UINT 0 1 0 1:1 X
159.9 Speed virtual master INT -32768 32767 256 1:1 X
159.10 Position virtual master DINT 0 0x7FFFFFFF 0 1:1 X
159.11 Input parameter UDINT 0 0xFFFFFFFF 0 1:1 X
159.12 Axis index input param-
eter
UINT 0 1 0 1:1 X
159.14 Basic value index calcu-
lation
UDINT 0 0xFFFFFFFF 0 1:1 X
159.15 Shift factor index calcu-
lation
UINT 0 32 0 1:1 X
159.16 Output parameter UDINT 0 0xFFFFFFFF 0 1:1 X
159.17 Target axis UINT 0 255 0 1:1 X