EasyManua.ls Logo

Baumuller b maXX BM5800 - Description of the Parameter

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
687
of 814
3
3.10.2.2 Description of the Parameter
101.1 Status
101.8 Channel 5 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.9 Channel 6 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.10. Channel 7 source
parameter Id
UDINT 0 4294967295 0 ID 1:1 X
101.11 Trigger source parame-
ter Id
UDINT 0 4294967295 0 ID 1:1 X X
101.12 Trigger mode UDINT 0 0x00000077 0 1:1 X X
101.13 Trigger axis mask UINT 0x1 0x3 0x1 1:1 X X
101.14 Trigger condition UDINT 0 0x0000003F 0 1:1 X X
101.15 Trigger compare value FLOAT -5.000000e+9 5.000000e+9 0.000000e+00 1:1 X X
101.16 Trigger compare mask UDINT 0 0xFFFFFFFF 0 1:1 X X
101.17 Trigger cause UINT 0 1999 0 1:1 X X
101.18 Sample time FLOAT 0.0000625 100 0.001 s 1:1 X X
101.19 After-Run time FLOAT 3.000000e-01 3.000000e+06 1.000000e+00 s 1:1 X X
101.20 Recording time FLOAT 1.000000e+01 3.000000e+06 1.000000e+01 s 1:1 X X
101.21 Buffer size UDINT 10000 504000 10000 DW 1:1 X X
101.22 Measure time FLOAT 0 10000 0 µs 1:1 X X
101.23 Scope buffer FLOAT -1.000000e+37 1.000000e+37 0.000000e+00 1:1 X X
101.24 Task number UINT 1 2 2 1:1 X X
Value Meaning
0 Recording stopped
1 Recording in progress
current status:
Waiting for trigger event
2 No significance
3 Trigger has occurred
Recording still in progress
Ring buffer in after-running period
4 Ring buffer can be read out

Table of Contents