EasyManua.ls Logo

Baumuller b maXX BM5800 - State Transitions in the Device Controller of the Axis Units

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
293
of 814
3
3.5.1.4 State Transitions in the Device Controller of the axis units
0 Input to the State Machine NOT READY TO SWITCH ON
n Event:
m Switch on supply to electronics
m Hardware reset or
m Software reset
n Action:
m Start initialization and self test
1 NOT READY TO SWITCH ON SWITCH-ON INHIBIT
n Event:
m Initialization and self test completed without error
n Action:
m None
2 SWITCH-ON INHIBIT READY TO SWITCH ON
n Event:
Drive activation by control word:
m "Shut-down" command
n Condition:
m axis not parked
n Action:
m None
3 READY TO SWITCH ON SWITCHED ON
n Event:
Drive activation by control word:
m "Switch On" command
n Condition:
m Power supply reports operational readiness / main supply voltage applied and
n Action:
m None
4 SWITCHED ON OPERATION ENABLED
n Event:
Drive activation by control word:
m "Enable Operation" command
n Action:
m Drive function is enabled and
m Holding brake is enabled
(only if brake is in Automatic mode (Parameter Z134.1 Bit 0 = 1)

Table of Contents