Management
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
294
of 814
3.5
5 OPERATION ENABLED OPERATION INHIBIT ACTIVE
n Event:
m "Inhibit Operation" command
n Action:
m Operation Inhibit is initiated (braked or coasted-down, depending on the setting)
5a OPERATION INHIBIT ACTIVE SWITCHED ON
n Event:
m INHIBIT response (P108.15) is set to "Inhibit Drive Function" (Pulse Inhibit, value
0) or
m Operation Inhibit has ended (speed 0 reached) and holding brake is applied (hold-
ing brake only relevant if brake is in Automatic mode (Parameter Z134.1–
Bit 0 = 1) and state monitoring (Parameter Z134.1– Bit 4 = 1) is switched on)
n Action:
m Drive function is inhibited
5b OPERATION INHIBIT ACTIVE OPERATION ENABLED
n Event:
m Operation Inhibit has ended (speed 0 reached) and holding brake could not be
applied (holding brake only relevant if brake is in Automatic mode (Parameter
Z134.1– Bit 0 = 1) and state monitoring (Parameter Z134.1– Bit 4 = 1) is
switched on) and
– Drive activation by control word:
m "Enable Operation" command
n Condition:
m INHIBIT response (Z108.15–) is not set to "Inhibit Drive Function" (Pulse Inhibit,
value 0)
n Action:
m Drive function is enabled
6 SWITCHED ON READY TO SWITCH ON
n Event:
m "Shut Down" command
n Action:
m None
7 READY TO SWITCH ON SWITCH-ON INHIBIT
n Event:
m "Quick Stop" command or
m "Inhibit Voltage" command
n Action:
m None