Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
295
of 814
3
8 OPERATION ENABLED DRIVE SHUT-DOWN ACTIVE
n Event:
m "Shut Down" command
n Action:
– Drive activation by control word:
m Drive shut-down is initiated (braked or coast-down, depending on setting)
8a DRIVE SHUT-DOWN ACTIVE READY TO SWITCH ON
n Event:
m SHUT-DOWN response (Z108.14–) is set to "Inhibit Drive Function" (Pulse Inhib-
it, value 0) or
m Drive Shut-down has ended (speed 0 reached) and holding brake is applied
(holding brake only relevant if brake is in Automatic mode (Parameter
Z134.1–
Bit 0 = 1) and state monitoring (Parameter Z134.1– Bit 4 = 1) is switched on)
n Action:
m Drive function is inhibited
8b DRIVE SHUT-DOWN ACTIVE OPERATION ENABLED
n Event:
m Drive Shut-down has ended (speed 0 reached) and holding brake could not be
applied (holding brake only relevant if brake is in Automatic mode (Parameter
134.1 Bit
0 = 1) and state monitoring (Parameter 134.1 Bit 4 = 1) is switched on)
or
– Drive activation by control word:
m "Enable Operation" command
– Drive activation by hardware control inputs:
n Condition:
m SHUT-DOWN response (Z108.14–) is not set to "Inhibit Drive Function" (Pulse
Inhibit, value 0)
n Action:
m Drive function is enabled
9 OPERATION ENABLED SWITCH-ON INHIBIT
n Event:
m "Inhibit Voltage" command
n Action:
m Drive function is inhibited
10 SWITCHED ON SWITCH-ON INHIBIT
n Event:
m "Inhibit Voltage" command or
m "Quick Stop" command
n Action:
m Drive function is inhibited