3.5
11 OPERATION ENABLED QUICK STOP ACTIVE
n Event:
m "Quick Stop" command
n Action:
m Quick Stop is initiated (braked or coast-down, depending on setting)
12 QUICK STOP ACTIVE SWITCH ON INHIBIT
n Event:
m "Inhibit Voltage" command or
m QUICK STOP response (Z108.13) is set to "Inhibit Drive Function" (Pulse Inhib-
it, value 0) or
m Quick Stop has ended (speed 0 reached) and holding brake is applied (holding
brake only relevant if brake is in Automatic mode (Parameter
Z134.1 Bit 0 = 1)
and state monitoring (Parameter Z134.1 Bit 4 = 1) is switched on)
n Action:
m Drive function is inhibited
16 QUICK STOP ACTIVE OPERATION ENABLED
n Event:
Drive activation by control word:
m "Enable Operation" command
n Condition:
m QUICK STOP response (Z108.13) is set to "Remain in Quick Stop" (value 5 to
8) or
QUICK STOP response (Z108.13) is not set to "Remain in Quick Stop" (value
less than 5) and Quick Stop has ended (speed reached 0) and the holding brake
could not be applied (holding brake only relevant if brake is in Automatic mode
(Parameter
Z134.1 Bit 0 = 1) and state monitoring (Parameter Z134.1
Bit 4 = 1) is switched on)
n Action:
m Drive function is enabled and
m Holding brake is enabled
(only if brake is in Automatic mode (Parameter Z134.1 Bit 0 = 1)
13 All states ERROR RESPONSE ACTIVE
n Event:
m Drive error is detected, i.e., an error to which a response should follow has been
triggered
n Action:
m Error-dependent error response is initiated