EasyManua.ls Logo

Baumuller b maXX BM5800 - Parameter Overview

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Management
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
324
of 814
3.5
3.5.2.12 Parameter overview
Functional block: FbDsv [105]
Create Data Set <n> 6 Data set to be cre-
ated
Delete Data Set <n> 7 Data set to be
deleted
Copy Data Set <x> to Data Set <y> 8 Source data set Target data set
Load Data Set <x> from Flash 9 Data set in Flash
Set standard values for all axis spe-
cific parameters of an axis
10
Z105.1
Data Set Management
Command
Valu
e
Z105.8
Source data set
Z105.9
Target Data Set
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
105.1 Command DINT 0 10 0 1:1
105.2 Status UDINT 0 0xFFFFFFFF 0 1:1 X
105.3 Message RE-
CORD
X
105.4 Record name STRING 1:1 X
105.5 Record Id UDINT 0 0xFFFFFFFF 0 1:1 X
105.6 Dataset index UINT 1 7 1 1:1
105.7 ValidDatasets BIT-
FIELD
1 0x7F 1 1:1 X
105.8 DatasetSource UINT 0 7 0 1:1
105.9 DatasetDest UINT 0 7 0 1:1
105.10 Boot Mode SAF-XXX WORD 0 0xFFFF 1 1:1 X X
105.11 Name of complete para-
meter set
STRING 1:1 X X
105.12 Error count UINT 0 0xFFFF 0 1:1 X
105.13 Config Ident number UDINT 0 0xFFFFFFFF 0 1:1 X X