3.5
3.5.2.12 Parameter overview
Functional block: FbDsv [105]
Create Data Set <n> 6 Data set to be cre-
ated
Delete Data Set <n> 7 Data set to be
deleted
Copy Data Set <x> to Data Set <y> 8 Source data set Target data set
Load Data Set <x> from Flash 9 Data set in Flash
Set standard values for all axis spe-
cific parameters of an axis
10
Z105.1–
Data Set Management
Command
Valu
e
Z105.8–
Source data set
Z105.9–
Target Data Set
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
105.1 Command DINT 0 10 0 1:1
105.2 Status UDINT 0 0xFFFFFFFF 0 1:1 X
105.3 Message RE-
CORD
X
105.4 Record name STRING 1:1 X
105.5 Record Id UDINT 0 0xFFFFFFFF 0 1:1 X
105.6 Dataset index UINT 1 7 1 1:1
105.7 ValidDatasets BIT-
FIELD
1 0x7F 1 1:1 X
105.8 DatasetSource UINT 0 7 0 1:1
105.9 DatasetDest UINT 0 7 0 1:1
105.10 Boot Mode SAF-XXX WORD 0 0xFFFF 1 1:1 X X
105.11 Name of complete para-
meter set
STRING 1:1 X X
105.12 Error count UINT 0 0xFFFF 0 1:1 X
105.13 Config Ident number UDINT 0 0xFFFFFFFF 0 1:1 X X