3.5.3.3 ProDrive Brake Management
Figure 85: ProDrive brake management
3.5.3.4 Parameter overview
Functional block: FbBrakeMgr [134]
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
134.1 Mode DWORD 0 0xFFFFFFFF 0x22 1:1 X
134.2 Status DWORD 0 0xFFFFFFFF 0 1:1 X
134.3 Control automatic DWORD 0 0xFFFFFFFF 0 1:1 X
134.4 Command WORD 0 0xFFFF 0 1:1 X
134.5 Torque limit FLOAT -1.00E+06 1.00E+06 0 Nm 1:1 X X
134.6 Speed limit FLOAT 0 1.00E+06 90 Grad/s 1:1 X
134.7 Timeout check-back sig-
nal
UINT 0 1000 1000 ms 1:1 X
134.8 Pulse inhibit delay UINT 0 1000 500 ms 1:1 X
134.9 Start of motion delay UINT 0 1000 500 ms 1:1 X
134.10 Opening delay UINT 0 1000 0 ms 1:1 X

Table of Contents