Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
279
of 814
3
Conversion between Factor Group parameters and controller parameters:
Figure 77: Factor Group effect of position weighting
x
x
x
x
x
x
x
x
Position weighting unsigned
Position weighting unsigned
Position weighting unsigned
Position weighting unsigned
Position window P179.11
(0x6067)
Positioning positioning window (P121.5)
Position weighting signed
Target position P179.12
(0x607A)
Cyclic position set value specification
target position (P136.3)
Cyclic position set value specification
target angle (P136.5)
Positioning relative target position (P118.16)
1/ Position weighting unsigned
1/ Position weighting unsigned
1/ Position weighting unsigned
Home offset P179.13
(0x607C)
Home position (P120.3)
Minimum software position limit
P179.14
(0x607D.01)
Negative software limit switch (P121.3)
Maximum software position limit
P179.15
(0x607D.02)
Positive software limit switch (P121.4)
Position actual value P179.10
(0x6064)
Position actual angle for fieldbus (P18.76)
Position actual revolutions for fieldbus (P18.77)
Touch probe 1 pos. value P179.16
(0x60BA)
Touch probe 1 neg. value P179.17
(0x60BB)
Touch probe 2 pos. value P179.18
(0x60BC)
Touch probe 2 neg. value P179.19
(0x60BD)
Touch probe revolutions+angle
(selection with P124.30
from P124.5 ... 124.16 or 124.28)
Position error actual value P179.20
(0x60F4)
Position error rev+angle (P18.60)

Table of Contents