3.5.4.2 Description of the Parameters
100.1 Error command
Command for the Info Manager.
100.2 Error count
Returns the number of errors present in the error memory since the last switch-on or since
the last error reset.
100.3 Error information
Parameter displays the errors and warnings.
The parameter is an array with 20 entries. Each entry contents the error number as well
as the additional information as e.g. the time of the occurrence and the time of reset (rel
-
ative time since switch-on).
If errors are reset then these are shifted to the end of the array. By reading out the array
completely, it is possible to access error messages prior to the last reset.
The number of the relevant entries (i.e. the not yet acknowledged messages) is displayed
in parameter
Z100.2– Error count.
Value Meaning
0 Reserved
1 Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Z108.1– Control word 1 bit 7 as far as possible
2 Reset all error responses to the default values
4 Reset all errors
Parameter is supported for compatibility reasons, use instead of that
Z108.1– Control word 1 bit 7 as far as possible
5 Trigger application error no. 169
6 Reset error memory
7 Reset error memory (RAM, see Z100.12–)
Remain-
der
Reserved