3.7.6.3 Description of the Flux Controller parameters
146.10 Kp flux controller
Proportional gain of the flux controller.
The flux controller is switched off, if the proportional gain is less or equal to 0.1.
146.11 Tn flux controller
Reset time of the flux controller [ms]
146.12 Limit magnetizing current
Limitation of the flux controller’s output [A]
146.15 Actual flux current
Flux current [A]
146.18 Integral term flux controller
Integral term of the flux controller
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
146.10 Kp flux controller FLOAT 0 1e9 0 1/s 1:1 X
146.11 Tn flux controller FLOAT 0 10000 1000 ms 1:1 X
146.12 Limit magnetizing cur-
rent
FLOAT 0 1e9 10 A 1:1 X
146.15 Actual flux current FLOAT -1e9 1e9 0 A 1:1 X
146.18 Integral term flux con-
troller
FLOAT -1e9 1e9 0 A 1:1 X